AXIS#.IL.COGCOMP.TEACH.STATUS

Description

The status of the Cogging Compensation teach phase.

Versions

Action Version Notes
Implemented 02-08-00-000
Updated Range    

General Information

Type

Read Only

Units

N/A

Range
-4 Error - Motion Stopped Unexpectedly
-3 Error - Motion Did not Start
-2 Error - Axis Error
-1 Error - Unexpected Behavior
0 Idle
1 Running - Cogging Compensation Teach in Progress
2 Complete
3 Complete with Missing data

  • If the teach finishes with Complete with Missing Data, more than 0.5% of data points did not acquire data due to the axis moving too quickly. Reduce cogging table size, or reduce teach speed to eliminate missing data.
Default Value 0

Data Type

U8

Stored in Non-Volatile Memory

No

Variants Supported

All variants are supported.

Fieldbus Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

AXIS1.IL.COGCOMP.TEACH.STATUS

500ah

22h

Signed8

-

-

Read only

No

AXIS2.IL.COGTABLE.TEACH.STATUS

510ah

22h

Signed8

-

-

Read only

No

EtherNet/IP

ID

Instance

Attribute

Name

Data Type

Access

User Mappable

5853

1

5853 (0x16dd)

AXIS1.IL.COGCOMP.TEACH.STATUS

Signed8

Read Only

Yes

71389

2

5853 (0x16dd)

AXIS2.IL.COGCOMP.TEACH.STATUS

Signed8

Read Only

Yes

PROFINET

Parameter

PNU

Data Type

Access

Units

AXIS#.IL.COGCOMP.TEACH.STATUS

5853

Signed8

Read Only

-